The "µBio" application is a system to describe the mixing situation of the microorganism included in Sample that the embarkation researcher (microorganism researcher) gathered, and to preserve it in the data base. The data registered here is accumulated in the data base for the research. The data inspection system can inspect the accumulated data.
The flow of the processing of this software is as follows.
After starting the application, the Login dialog (Fig. 2.1) will appear and prompt you to enter your username and password.
Fig. 2.1 Login dialog
After logging in, the menu dialog will open. If the entered username or/and password are invalid or if the user doesn't have permission to use this application, an error dialog (Fig. 2.2, Fig. 2.3) will appear and request that you login again.
Fig. 2.2 Login failure dialog - invalid username or password
Fig. 2.3 Login failure dialog - user doesn't have permission
Microbiologist can use all functions in this application.
To change your password, click the
button at the bottom right of the Login dialog.
The Change Password dialog will be displayed (Fig. 2.4).
Fig. 2.4 Change Password dialog
Type your login ID, your current password, a new password,and retype the new password. After filling all fields, click the "OK" button. When your password is accepted, the Login dialog will be activated. Otherwise an error dialog will be displayed.
When your logging-in is succeeded, the "µBio Menu dialog " will be shown (Fig. 2.5). In this dialog, you can select edit object Expedition. Only Expedition that can be edited can be selected. (Editing only Current Expedition as a rule becomes possible in the shipboard. )
Fig. 3.1 µBio Menu dialog
To select Expedition,
When Expedition is selected, Sample List Display of object Expedition is displayed. (Fig. 4.1) The object sample and the function (kind of data that registers =) to register data are selected on this screen. Moreover, the confidence lower detection limit setting screen can be called.
Fig. 4.1 Sample List Display
In an initial display, the value of "confidence lower detection limit" that relates to the selected Expedition is displayed. (Fig.4.2)
Fig. 4.2 Sample List Display (Initial display)
In confidence lower detection limit, the following four are in the kind and each unit of data.
When the value has already been registered, the numerical value is displayed. When the value is not registered, it is displayed, "Undefined".
The confidence lower detection limit editor is displayed
when the "Edit" button in the "confidence lower detection limit frame" is pushed,
and the confidence lower detection limit value can be edited. (
5. Editing Confidence Lower Detection Limit Data)
There is
button next to confidence lower detection limit frame.
Clicking on this button shows the Application Information Dialog.
The user is requested to specify the web browser to use prior to display the document.
This button is also in other some screens.
The called one is always the same dialog even if pushed on which screen.
To register data, Sample that first becomes an object is selected. To select Sample, it narrows it by Site and Hole. The narrowing condition is set in order of Site and Hole.
Site List:
Site of selected Expedition is choices. Arbitrary Site or "All Sites" is selected. (Fig.4.3)Hole List:
"All Sites" is selected from the Site list, Hole of selected Site is choices. Arbitrary Hole or "All Holes" is selected. (Fig.4.4)
Fig. 4.3 Site list
Fig. 4.4 Hole list
When Site and Hole are selected, the "Query" button is pushed. Then, it narrows by Site and Hole and the list of retrieved Sample is displayed on the screen. (Fig.4.5)
The following columns are displayed in the sample list.
Sample that registers data is searched out from Sample List. The object line enters the state of the selection if the mouse is clicked on target Sample. (Fig.4.6)
Fig. 4.5 Sample List Display (sample list)
Fig. 4.6 Sample List Display (selecting a sample)
Four kinds of data groups can register in this application. Each registration function is as follows.
The button of a target function is pushed with Sample of the object selected to use the registration function.
Fig. 4.7 Sample List Display (selecting a function)
The confidence lower detection limit value is registered on this screen. (Fig.5.1)
Fig. 5.1 Confidence Lower Detection Limit Editor
To edit values,
The preservation method of the specified sample is registered on this screen. (Fig.6.1, Fig.6.2)
Fig. 6.1 Sample Preservation Editor
Fig. 6.2 Sample Preservation Editor
To edit values,
The biomass analysis result of the specified sample (ie. cell density, stain reagent, comment etc.) is registered on this screen. (Fig.7.1, Fig.7.2)
Fig. 7.1 Total Cells Editor
Fig. 7.2 Total Cells Editor
To edit values,
The microscope image used for the biomass measurement is registered on this screen. (Fig.8.1)
Fig. 8.1 Microscope Image Editor
Please refer to "Common User Interface: Registering microphotographs" for the usage of the dialog.
The result of the contamination test of PFC is registered on this screen. (Fig.9.1)
Fig. 9.1 PFC Test Editor
To edit values,
The result of the Contamination test with a fluorescent bead and a fluorescence microscope is registered on this screen. (Fig.10.1)
Fig. 10.1 Beads Test Editor
To edit values,